The Dynon forum was helpful and provided some information on connecting the EarthX LED to the Dynon EMS:
https://forum.flydynon.com/threads/earthx-lithium-battery-bms-configuration.11789/
1) Connect the EarthX fault monitoring wire to any unused General Purpose input (type = A or C) on the SV-EMS-220. (Pins 4, 7, 8, 9, 10, 11, 12, 20, 21, 22, 23, or 31)
2) Configure the input in the EMS SETUP> SENSOR INPUT MAPPING. FUNCTION = CONTACT, SENSOR = CONTACT, NAME = EARTHX (select CUSTOM and enter a suitable name)
3) Configure the EARTHX CONTACT in EMS SETUP> SESNOR SETUP.
ALARM = SELF-CLEARING
MAXIMUM GRAPHICAL DISPLAY = 5.0 VOLTS
MINIMUM GRAPHICAL DISPLAY = 0.0 VOLTS
RANGE 1
ENABLE = YES
NAME = ALRM
COLOR = RED
TOP = 1.0 VOLTS
BOTTOM = 0.0 VOLTS
RANGE 2
ENABLE = YES
NAME = (NOT SET)
COLOR = BLACK
TOP = 5.0 VOLTS
BOTTOM = 1.0 VOLTS
Ranges 3, 4, and 5: ENABLE = NO
4) Place the EARTHX CONTACT widget on the 100%, 50%, and 20% EMS screens using the EMS-SETUP> SCREEN LAYOUT EDITOR